527 research outputs found

    Measurement on Different MLI Systems Between 77 K and 4 K and their Application in Cryogenic Engineering

    Get PDF
    Precise thermal measurements were done on different types of large surface MLI samples under various boundary conditions. The measurements were focused on the use of MLI for large industrial plants considering quick and simple installation. The results of the measurements aim at optimising MLI parameters, which control the thermal behaviour. Practical recommendations of MLI materials and their installation are given

    Measurements of Multi-Layer Insulation at High Boundary Temperature, using a Simple Non-Calorimetric Method

    Get PDF
    In spite of abundant literature, the thermal performance of Multi-Layer Insulation (MLI) still deserves dedicated investigation for specific applications, as the achievable insulation strongly depends on installation details. Furthermore, less accurate information is available for warm than for cold boundaries, since errors due to edge effects in small test benches increase strongly with warm boundary temperature. We establish here the thermal performance of MLI between 300 K and 77 K or 4 K, without bringing calorimetric methods into play, through the accurate measurement of a temperature profile. A cylinder in thin copper, wrapped with MLI, is cooled at one extremity while suspended under vacuum inside a sheath at room temperature. For known thermal conductivity and thickness of the tube, the heat flux can be inferred from the temperature profile. In-situ measurement of the thermal conductivity is obtained by applying a know heat flow at the warm extremity of the cylinder. Results, cross-checked with a calibrated heatmeter, compare well with what previously obtained on a large-scale measuring facility

    Cryogenic R&D at the CERN Central Cryogenic Laboratory

    Get PDF
    The Central Cryogenic Laboratory operates since many years at CERN in the framework of cryogenic R&D for accelerators and experiments. The laboratory hosts several experimental posts for small cryogen ic tests, all implemented with pumping facility for GHe and vacuum, and is equipped with a He liquefier producing 6.105 l/year, which is distributed in dewars. Tests include thermomechanical qualifica tion of structural materials, cryogenic and vacuum qualification of prototypes, evaluation of thermal losses of components. Some of the most relevant results obtained at the laboratory in the last yea rs are outlined in this paper

    Molecular-dynamics study of collision, implantation, and fragmentation of Ag7 on Pd(100)

    Get PDF
    By using embedded-atom-method interatomic potentials and molecular-dynamics simulations, we study the collision of a single Ag/sub 7/ cluster on the Pd(100) substrate, at impact energies in the direction perpendicular to the (100) surface E/sub 1/=20 eV (2.86 eV/atom) and E/sub 2/=95 eV (13.6 eV/atom). Our results indicate that implantation occurs at both impact energies, but it is more important at E/sub 2/. As opposed to what is shown experimentally, little fragmentation takes place for E/sub 1/, while the calculated cluster fragmentation is in good agreement with the experimental data for E/sub 2/

    Status of the HIE-ISOLDE project at CERN

    Full text link
    The HIE-ISOLDE project represents a major upgrade of the ISOLDE nuclear facility with a mandate to significantly improve the quality and increase the intensity and energy of radioactive nuclear beams produced at CERN. The project will expand the experimental nuclear physics programme at ISOLDE by focusing on an upgrade of the existing Radioactive ion beam EXperiment (REX) linac with a 40 MV superconducting linac comprising thirty-two niobium-on-copper sputter-coated quarter-wave resonators housed in six cryomodules. The new linac will raise the energy of post-accelerated beams from 3 MeV/u to over 10 MeV/u. The upgrade will be staged to first deliver beam energies of 5.5 MeV/u using two high-β\beta cryomodules placed downstream of REX, before the energy variable section of the existing linac is replaced with two low-β\beta cryomodules and two additional high-β\beta cryomodules are installed to attain over 10 MeV/u with full energy variability above 0.45 MeV/u. An overview of the project including a status summary of the different R&D activities and the schedule will outlined.Comment: 7 pages, 12 figures, submitted to the Heavy Ion Accelerator Technology conference (HIAT) 2012, in Chicag

    Heat Flow Measurements on LHC Components

    Get PDF
    The refrigeration and liquefaction capacity necessary to operate at 1.9 K the 27 km long string of superconducting magnets of the LHC has been determined on the basis of heat load estimates, including static heat inleaks from ambient temperature, resistive heating and dynamic beam-induced heat loads. At all temperature levels, the static heat inleaks determine at least one third of the total heat loads in nominal operating conditions of the machine. Design validation of individual cryocomponents therefore requires a correct estimate of the heat inleaks they induce at all temperature levels, in order not to exceed the allocated heat budget. This paper illustrates the measurements of heat inleaks for several cold components of the future machine, including insulating supports, radiation shields, multi-layer insulation, instrumentation current leads. Distinct methods to determine the heat flow are chosen, depending on the expected heat loads, the temperature range spanned by the heat intercepts, and the working conditions of the component itself

    A Facility for Accurate Heat Load and Mass Leak Measurements on Superfluid Helium Valves

    Get PDF
    The superconducting magnets of the Large Hadron Collider (LHC) will be protected by safety relief valves operating at 1.9 K in superfluid helium (HeII). A test facility was developed to precisely determine the heat load and the mass leakage of cryogenic valves with HeII at their inlet. The temperature of the valve inlet can be varied from 1.8 K to 2 K for pressures up to 3.5 bar. The valve outlet pipe temperature can be regulated between 5 K and 20 K. The heat flow is measured with high precision using a Kapitza-resistance heatmeter and is also crosschecked by a vaporization measurement. After calibration, a precision of 10 mW for heat flows up to 1.1 W has been achieved. The helium leak can be measured up to 15 mg/s with an accuracy of 0.2 mg/s. We present a detailed description of the test facility and the measurements showing its performances

    “CoVidentary”: An online exercise training program to reduce sedentary behaviours in children with type 1 diabetes during the COVID-19 pandemic

    Get PDF
    Aim: We explored the physical activity (PA) level and the variation in glycaemic control in children with type 1 diabetes (T1D) before and during the lockdown. Then, we proposed an online training program supported by sport-science specialists. Methods: Parents of children with T1D (<18 years) filled out an online survey. Anthropometric characteristics, PA, play, sport and sedentary time and the medical related outcomes were recorded. An adapted online program “Covidentary” was proposed through full-training (FT) and active breaks (AB) modality. Results: 280 youth (11.8 ± 3.3 years) were included in the analysis. We reported a decline in sport (-2.1 ± 2.1 h/week) and outdoor-plays (-73.9 ± 93.6 min/day). Moreover, we found an increase in sedentary time (+144.7 ± 147.8 min/day), in mean glycaemic values (+25.4 ± 33.4 mg/dL) and insulin delivery (71.8% of patients). 37% of invited patients attended the training program, 46% took part in AB and 54% in FT. The AB was carried out for 90% of the total duration, while the FT for 31%. Both types of training were perceived as moderate intensity effort. Conclusion: A decline of participation in sport activities and a subsequent increase of sedentary time influence the management of T1D of children, increasing the risk of acute/long-term complications. Online exercise program may contrast the pandemic's sedentary lifestyle

    Surface mobility of Ag on Pd(100) measured by specular helium scattering

    Get PDF
    We study the deposition and the very first steps of nucleation and growth of Ag on Pd(100) with thermal energy atom scattering. This technique is a very sensitive and nonperturbing probe to surface point defects, which permits an in situ and in-time monitoring of the deposition. The intention of this paper is to give a detailed description of the approach used in our work. The form of the specularly reflected helium signal as a function of coverage and surface temperature is compared to a theoretical curve, which is computed by solving a system of rate equations that describe the formation and destruction of clusters during the deposition process. The analysis of the experimental data gives two main results. The diffusion parameters (activation barrier E/sub d/=0.37+or-0.03 eV and preexponential factor nu /sub 0/=8*10/sup 9/ s/sup -1/) have been extracted for the system Ag on Pd(100). We find furthermore that all silver atoms impinging on a zone of 6.1 AA around an adatom on the surface are captured by it at surface temperatures well below the onset of thermally activated mobility. The origin of this phenomenon is discussed and tentatively assigned to a combined effect of transient and neighbor driven mobility

    Morphology and evolution of size-selected metallic clusters deposited on a metal surface: Ag19+ / Pd(100)

    Get PDF
    We study size-selected deposition of Ag/sub 19//sup +/ clusters on Pd(100) at total kinetic energies of 20 and 95 eV using thermal energy atom scattering and molecular-dynamics simulations. Contrary to the case of Ag/sub 7/ where fragmentation is crucial to explain the data, the deposition leads at low temperature to noncompact structures localized around the impact point. We propose a model in which morphology changes take place between 200 and 300 K resulting in well-separated compact structures
    • …
    corecore